8000S Patient Monitor

Features

  • 10.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
  • 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
  • Efficient resistance to interference of defibrillator and electrosurgical cautery;
  • SPO2 can testing for 0.1% Weak;
  • RA-LL impedance Respiration;
  • Trend Coexist Display;
  • OxyCRG DyNamic View Display;
  • Bed to Bed view Display;
  • Networking capacity and nurse calling system;
  • Options of IBP, EtCO2, Central Monitoring System;
  • Built-in rechargeable battery 4400mAh;
  • 10.1″ high resolution color TFT LCD display;
  • Large volume of tabular and graphic trends information storage and easy to recall;
  • Anti-ESU, anti- defibrillator;
  • Capture dynamic waveforms.
Category:

Features

  • 10.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
  • 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
  • Efficient resistance to interference of defibrillator and electrosurgical cautery;
  • SPO2 can testing for 0.1% Weak;
  • RA-LL impedance Respiration;
  • Trend Coexist Display;
  • OxyCRG DyNamic View Display;
  • Bed to Bed view Display;
  • Networking capacity and nurse calling system;
  • Options of IBP, EtCO2, Central Monitoring System;
  • Built-in rechargeable battery 4400mAh;
  • 10.1″ high resolution color TFT LCD display;
  • Large volume of tabular and graphic trends information storage and easy to recall;
  • Anti-ESU, anti- defibrillator;
  • Capture dynamic waveforms.

Technical Specification

ECG

  • Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
  • Lead selection: I, II, III, avR, avL, avF, V,
  • Waveform: 2 ch
  • Lead mode: 3 Leads (R, L, F or RA, LA, LL)
  • Lead selection: I, II, III,
  • Waveform: 1 ch
  • Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

Heart Rate and Alarm

  • Range
  • Adult: 15 ~ 300 bpm
  • Neo/Ped: 15 ~ 350 bpm
  • Accuracy: ± 1% or ± 1bpm, which great
  • Resolution: 1 bpm
  • Sensitivity: > 200 (uV P-P)
  • Differential Input Impedance: > 5 MΩ
  • CMRR
    • Monitor: > 105 dB
    • Operation: > 105 dB
    • Diagnosis: > 85 dB
  • Electrode offset potential: ±300mV
  • Leakage Current: < 10 uA
  • Baseline Recovery: < 3 S after Defi.
  • ECG Signal Range: ±8 m V (Vp-p)
  • Bandwidth
    • Surgery: 1 ~ 15 Hz
    • Monitor: 0.5 ~ 35 Hz
    • Diagnostic: 0.05 ~ 100 Hz
  • Calibration Signal: 1 (mV p-p), Accuracy: ±5%
  • ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
  • ARR Detecting
  • Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
  • Alarm: Available
  • Review: Available

Respiration

  • Method: Impedance between R-F (RA-LL)
  • Differential Input Impedance: >2.5 MΩ
  • Measuring Impedance Range: 0.3~5.0Ω
  • Base line Impedance Range: 0 – 2.5 KΩ
  • Bandwidth: 0.3 ~ 2.5 Hz
  • Resp. Rate
  • Measuring and Alarm Range
  • -Adult: 0 ~ 120 rpm
  • -Neo/Ped: 0 ~ 150 rpm
  • Resolution: 1 rpm
  • Accuracy: ±2 rpm
  • Apnea Alarm: 10 ~ 40 S

NIBP

  • Method: Oscillometric
  • Mode: Manual, Auto, STAT
  • Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
  • 120, 180, 240,480 (Min)
  • Measuring Period in STAT Mode: 5 Min
  • Pulse Rate Range: 40 ~ 240 bpm
  • Alarm Type: SYS, DIA, MEAN
  • Measuring and alarm range
  •   Adult Mode
    • SYS: 40 ~ 270 mmHg
    • DIA: 10 ~ 215 mmHg
    • MEAN: 20 ~ 235 mmHg
  •   Pediatric Mode
    • SYS: 40 ~ 200 mmHg
    • DIA: 10 ~ 150 mmHg
    • MEAN: 20 ~ 165 mmHg
  • Neonatal Mode
    • SYS: 40 ~ 135 mmHg
    • DIA: 10 ~ 100 mmHg
    • MEAN: 20 ~ 110 mmHg
  • Resolution Pressure: 1mmHg
  • Accuracy Pressure Maximum Mean error: ±5mmHg
  • Maximum Standard deviation: ±8mmHg
  • Overpressure Protection
    • Adult Mode: 297±3 mmHg
    • Pediatric Mode: 240±3 mmHg
    • Neonatal Mode: 147±3 mmHg

SpO2

  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified
  • Actualization interval: about 1 Sec.
  • Alarm Delay: 10 Sec.
  • Pulse Rate
  • Measuring and Alarm Range: 20~300bpm
  • Resolution: 1bpm
  • Accuracy: ±2bpm

Temperature

  • Channel: 2
  • Measuring and Alarm Range: 0 ~ 50 °C
  • Resolution: 0.1°C
  • Accuracy: ±0.1°C
  • Actualization interval: about 1 Sec.
  • Average Time Constant:<10 Sec.

IBP (optional)

  • Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Measuring and alarm range
  • -ART: 0 ~ 300 mmHg
  • -PA: -6 ~ 120 mmHg
  • -CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
  • -P1/P2: -10 ~ 300 mmHg
  • Press Sensor
  • Sensitivity: 5 uV/V/mmHg
  • Impedance: 300-3000Ω
  • Resolution: 1 mmHg
  • Accuracy: ±2% or ±1mmHg, which great
  • Actualization interval: about 1 Sec

Standard Packing List

  • 5-lead ECG cable (including RESP)
  • Adult finger SpO2 sensor
  • Adult NIBP cuff
  • NIBP extension tube
  • TEMP sensor
  • AC power adaptor
  • ECG electrodes
  • Operation instruction

Optional Function

IBP, EtCO2, Central Monitoring System